Test and training system multi-joint module with isokinetic, isometric and
isotonic movement modes
. Computer supported test and training system for measuring and training the neuromuscular capacity of all major joints of the upper and lower limbs in the open kinetic chain.
Features
• The system is a testing and training machine for all major joints of the upper and lower limbs in the open kinetic chain.
• Sampling Rate: 4000 Hz sampling rate gives to the system a lot of options to realize not only excellent output results, but also from engineering site smooth motion of the adapters.
•Torque – Speed Range: 720 Nm in concentric and eccentric mode 0,1°/sec – 500°/sec
• Separate footplates allow unilateral (selectable left or right), bilateral and alternating movements.
• The back rest of the seat is electronic adjustable.
• The system includes following movement modes:
o Isometric Testing: Able to safely position the patient to each angle in the protocol. Protocol options include angles, hold-times, rest periods, repetitions, and sets.
o Isokinetic Testing: The system provides concentric and eccentric (Con/Con, Ecc/Ecc / Con/Ecc, Ecc/Con) and mixed modes (Con/CPM, CPM/Con, CPM/Ecc, Ecc/CPM).
o Ballistic mode for isokinetics and isotonics to measure patients/subjects in reasonable movement velocities
• The system includes real-time visual feedback curves to improve the range of motion, stability and muscle control.
• The system includes a 3-level safety system based on mechanic and software-controlled mechanism.
• Software features:
o the system allows for easy setup of patient or anonymous subjects. The software should automatically apply test or training protocol used from the most recent session.
o The software should allow for active compensation of gravity in the total movement pattern to compensate weight of limb and adapter during measurement / training.
o The software controls the stepless adjustable mechanical stops for safety.
o The system should include auxiliary outputs for easy access to torque, position, and direction analogue signals for input into other systems such as EMG.
o The system should offer a variety of easy-to-read, easy-to interpret reports. Full-page reports are in color and can be printed, previewed. Raw data is automatically saved for export to Excel or other formats.
Technical data
• Power Supply: Input Voltage 230 VAC, Input Frequencies 50 or 60 Hz
• Dimension: 2030 mm / 735 mm / 1520 mm
• Weight: 370 kg
• Maximum Patient Weight: 200 kg